Effectiveness of some conventional seismic retrofitting techniques for bare and infilled R/C frames

Απόθεσις

 

Εμφάνιση απλής εγγραφής

dc.contributor.author Kakaletsis, Demetrios
dc.contributor.author David, Konstantinos
dc.contributor.author Karayannis, C. G.
dc.date.accessioned 2015-06-16T09:55:19Z
dc.date.available 2015-06-16T09:55:19Z
dc.date.issued 2011-08
dc.identifier.other http://www.researchgate.net/profile/Kakaletsis_Demetrios/publication/264154391_Effectiveness_of_some_conventional_seismic_retrofitting_techniques_for_bare_and_infilled_RC_frames/links/540d59df0cf2f2b29a383b6f.pdf el
dc.identifier.uri http://apothesis.teicm.gr/xmlui/handle/123456789/1307
dc.description.abstract The effectiveness of a technique for the repair of reinforced concrete members in combination with a technique for the repair of masonry walls of infilled frames, damaged due to cyclic loading, is experimentally investigated. Three single - story, one - bay, 1/3 - scale frame specimens are tested under cyclic horizontal loading, up to a drift level of 4%. One bare frame and two infilled frames with weak and strong infills, respectively, have been tasted. Specimens have spirals as shear reinforcement. The applied repair technique is mainly based on the use of thin epoxy resin infused under pressure into the crack system of the damaged RC joint bodies, the use of a polymer modified cement mortar with or without a fiberglass reinforcing mesh for the damaged infill masonry walls and the use of CFRP plates to the surfaces of the damaged structural RC members, as external reinforcement. Specimens after repair, were retested in the same way. Conclusions concerning the effectiveness of the applied repair technique, based on maximum cycles load, loading stiffness, and hysteretic energy absorption capabilities of the tested specimens, are drawn and commented upon. en
dc.format.extent 23 el
dc.language.iso en el
dc.rights Attribution-NonCommercial-NoDerivatives 4.0 Διεθνές *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/ *
dc.title Effectiveness of some conventional seismic retrofitting techniques for bare and infilled R/C frames en
dc.type Άρθρο σε επιστημονικό περιοδικό el
dc.identifier.doi 10.12989/sem.2011.39.4.499
dc.publication.category Δημοσίευση ανοιχτής πρόσβασης el
dc.relation.journal Structural Engineering and Mechanics;Vol. 39, No. 4
dc.subject.keyword Infilled RC frames el
dc.subject.keyword Masonry strength el
dc.subject.keyword Repair technique el
dc.subject.keyword Experimental results el


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Τύπος Προβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής

Attribution-NonCommercial-NoDerivatives 4.0 Διεθνές Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Διεθνές